ISO 9001 · ISO 14001 · ISO 45001 certified manufacturer+91 82002 09166office@satyendrafinechem.com
Satyendra Fine Chem

Products · Mineral acids · product 26100

Nitric acid

Produced at concentrations from 60 % up to 70 %, with grades running from technical through to sub-ppb ultrapure.

Grades

Grade 26100·00

Technical

Nitric acid 60–62 %

Typical applications
Bulk process chemistry, metal pickling and passivation
Standard / basis
Manufactured to our internal specification
Density
1.37 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
5 LHDPE container261000044
25 LHDPE container261000062
200 LHDPE container261000064
1000 LIBC tank261000081
16,000 LRoad tanker261000082

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)60.0 – 62.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, free from suspended matterVisual, against water in matched tubes
Colour≤ 50APHAAPHA / Hazen, ASTM D1209
Residue after ignition≤ 0.01%Gravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Sulphate (SO₄)≤ 0.005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Iron (Fe)≤5ppmICP-MS / ICP-OES

Grade 26100·01

Laboratory Reagent

Nitric acid 69 %

Typical applications
General laboratory work, sample digestion, glassware cleaning
Standard / basis
Meets ISO 6353-2 requirements for laboratory reagents
Density
1.41 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
500 mLAmber glass bottle261000123
2.5 LAmber glass bottle261000142
5 LHDPE container261000144
25 LHDPE container261000162
200 LHDPE container261000164
1000 LHDPE container261000181

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)68.0 – 70.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, colourless liquidVisual, against water in matched tubes
Colour≤ 20APHAAPHA / Hazen, ASTM D1209
Residue after ignition≤ 0.002%Gravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.0005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Sulphate (SO₄)≤ 0.001%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Phosphate (PO₄)≤ 0.0005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Iron (Fe)≤ 0.0002%ICP-MS / ICP-OES
Heavy metals (as Pb)≤ 0.0005%Sulfide colorimetric limit test (as Pb), ACS

Grade 26100·02

Analytical Reagent

Nitric acid 69–70 %

Typical applications
Quantitative analysis, AAS and ICP digestion, pharmacopoeial testing
Standard / basis
Complies with ACS Reagent Chemicals, ISO 6353-2 and Ph. Eur. requirements
Density
1.41 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
500 mLAmber glass bottle261000223
2.5 LAmber glass bottle261000242
5 LHDPE container261000244
25 LHDPE container261000262
200 LHDPE container261000264
1000 LHDPE container261000281

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)69.0 – 70.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, colourless liquidVisual, against water in matched tubes
Colour≤ 10APHAAPHA / Hazen, ASTM D1209
Residue after ignition≤ 0.0005%Gravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.00002%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Sulphate (SO₄)≤ 0.00005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Phosphate (PO₄)≤ 0.00002%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Arsenic (As)≤ 0.005ppmHydride-generation AAS / ICP-MS
Iron (Fe)≤ 0.00002%ICP-MS / ICP-OES
Heavy metals (as Pb)≤ 0.00002%Sulfide colorimetric limit test (as Pb), ACS

Grade 26100·03

PV Pure

Nitric acid 67–69 %

Typical applications
Photovoltaic wafer texturing and etching, module manufacturing
Standard / basis
Manufactured to our PV Pure specification
Density
1.40 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
25 LHDPE container261000362
200 LHDPE container261000364
1000 LIBC tank261000381

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)67.0 – 69.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, colourless liquidVisual, against water in matched tubes
Colour≤ 10APHAAPHA / Hazen, ASTM D1209
Residue after ignition≤ 0.0005%Gravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.00005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Total metallic impurities≤1ppmICP-OES / ICP-MS, sum of listed elements

Trace metals — limits in ppb (µg/l) · 10 elements

AlAluminium≤ 100
CaCalcium≤ 100
CrChromium≤ 100
CuCopper≤ 100
FeIron≤ 100
MgMagnesium≤ 100
NiNickel≤ 100
KPotassium≤ 100
NaSodium≤ 100
ZnZinc≤ 100

Trace metals are determined by ICP-MS in our Class 100 clean-room laboratory after high-purity dilution, and the limits apply to the product as packed. Once an ultrapure pack is opened, the trace-metal specification can no longer be guaranteed.

Grade 26100·04

Ultrapure PPB

Nitric acid 67–69 %

Typical applications
Semiconductor processing, trace metal analysis, ICP and AAS work
Standard / basis
Trace metals to our ultrapure specification below
Density
1.40 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
500 mLClear glass / PU-coated Safebreak / FEP261000423
1 LClear glass / PU-coated Safebreak / FEP261000441
2.5 LClear glass / PU-coated Safebreak / FEP261000442

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)67.0 – 69.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, colourless liquidVisual, against water in matched tubes
Colour≤ 10APHAAPHA / Hazen, ASTM D1209
Residue after evaporation≤ 0.0005%Gravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.00002%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Sulphate (SO₄)≤ 0.00005%Turbidimetric / colorimetric limit test (ACS) or ion chromatography
Particles > 0.5 µm≤ 100per mlLiquid-borne particle counter (light scattering)

Trace metals — limits in ppb (µg/l) · 65 elements

AlAluminium≤1
SbAntimony≤ 0.5
AsArsenic≤ 0.5
BaBarium≤ 0.1
BeBeryllium≤ 0.1
BiBismuth≤ 0.1
BBoron≤1
CdCadmium≤ 0.5
CsCaesium≤ 0.1
CaCalcium≤1
CeCerium≤ 0.1
CrChromium≤ 0.5
CoCobalt≤ 0.5
CuCopper≤ 0.5
DyDysprosium≤ 0.1
ErErbium≤ 0.1
EuEuropium≤ 0.1
GdGadolinium≤ 0.1
GaGallium≤ 0.1
GeGermanium≤ 0.1
AuGold≤ 0.1
HfHafnium≤ 0.1
HoHolmium≤ 0.1
InIndium≤ 0.1
IrIridium≤ 0.1
FeIron≤1
LaLanthanum≤ 0.1
PbLead≤ 0.2
LiLithium≤ 0.3
LuLutetium≤ 0.1
MgMagnesium≤1
MnManganese≤ 0.3
HgMercury≤ 0.1
MoMolybdenum≤ 0.3
NdNeodymium≤ 0.1
NiNickel≤ 0.5
NbNiobium≤ 0.1
OsOsmium≤1
PdPalladium≤ 0.5
PtPlatinum≤ 0.5
KPotassium≤1
PrPraseodymium≤ 0.1
ReRhenium≤ 0.1
RhRhodium≤ 0.1
RbRubidium≤ 0.1
RuRuthenium≤ 0.5
SmSamarium≤ 0.1
ScScandium≤ 0.1
SeSelenium≤1
AgSilver≤ 0.1
NaSodium≤1
SrStrontium≤ 0.3
TaTantalum≤ 0.1
TeTellurium≤ 0.1
TbTerbium≤ 0.1
TlThallium≤ 0.1
TmThulium≤ 0.1
SnTin≤ 0.5
TiTitanium≤ 0.5
WTungsten≤ 0.5
VVanadium≤ 0.5
YbYtterbium≤ 0.1
YYttrium≤ 0.1
ZnZinc≤ 0.5
ZrZirconium≤ 0.1

Trace metals are determined by ICP-MS in our Class 100 clean-room laboratory after high-purity dilution, and the limits apply to the product as packed. Once an ultrapure pack is opened, the trace-metal specification can no longer be guaranteed.

Grade 26100·05

Ultrapure PPT

Nitric acid 67–69 %

Typical applications
ICP-MS trace analysis, advanced wafer fabrication, ultratrace digestion
Standard / basis
Trace metals at parts-per-trillion level — limits set from batch validation
Density
1.40 g/ml (20 °C)

Pack sizes and SKUs

PackContainerSKUAdd
250 mLFEP bottle, clean-room packed261000522
500 mLFEP bottle, clean-room packed261000523
1 LFEP bottle, clean-room packed261000541

Release specification

ParameterLimitUnitMethod (typical)
Assay (HNO₃)67.0 – 69.0%Titrimetry (acid–base / redox), ACS / Ph. Eur. method
AppearanceClear, colourless liquidVisual, against water in matched tubes
Colour≤ 10APHAAPHA / Hazen, ASTM D1209
Residue after evaporation≤ 0.0001%Gravimetric, ACS Reagent Chemicals
Particles > 0.5 µm≤ 25per mlLiquid-borne particle counter (light scattering)

Trace metals at parts-per-trillion level · 65 elements monitored

Limits for this grade come from batch validation. Each certificate of analysis reports them at ppt level.

Al Sb As Ba Be Bi B Cd Cs Ca Ce Cr Co Cu Dy Er Eu Gd Ga Ge Au Hf Ho In Ir Fe La Pb Li Lu Mg Mn Hg Mo Nd Ni Nb Os Pd Pt K Pr Re Rh Rb Ru Sm Sc Se Ag Na Sr Ta Te Tb Tl Tm Sn Ti W V Yb Y Zn Zr

Reference standards

  • Laboratory Reagent (LR): meets ISO 6353-2 requirements for laboratory reagents.
  • Analytical Reagent (AR): complies with ACS Reagent Chemicals (current edition), ISO 6353-2 and Ph. Eur. monograph requirements where a monograph exists.
  • PV Pure: our photovoltaic specification — ten named metallic elements limited per the table for the grade.
  • Ultrapure / Electronic grades: trace metals controlled to our ultrapure specification (ICP-MS, 65 elements). The parameter set follows SEMI C35 — Specification and Guide for Nitric Acid; conformance to a specific SEMI grade or tier is confirmed per lot on the certificate of analysis and can be contracted on request.
  • Test methods listed as "typical" are our release methods; equivalent ACS, Ph. Eur. or SEMI C1 methods may be substituted by agreement.

Limits shown as "≤" are the maximum values a lot is released against, and an assay range is the guaranteed window. We manufacture tightened limits, bespoke concentrations and non-standard packs to order.