Products · Mineral acids · product 25300
Hydrochloric acid
Our founding product. From technical-grade acid in road tankers to clean-room-filled PPT acid for ICP-MS.
Grades
Grade 25300·00
Technical
Hydrochloric acid 30–34 %
- Typical applications
- Bulk process chemistry, pickling, water treatment, resin regeneration
- Standard / basis
- Manufactured to our internal specification
- Density
- 1.15 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 5 L | HDPE container | 253000044 | |
| 25 L | HDPE container | 253000062 | |
| 200 L | HDPE container | 253000064 | |
| 1000 L | IBC tank | 253000081 | |
| 16,000 L | Road tanker | 253000082 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 30.0 – 34.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, free from suspended matter | Visual, against water in matched tubes | |
| Colour | ≤ 50 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after ignition | ≤ 0.01 | % | Gravimetric, ACS Reagent Chemicals |
| Iron (Fe) | ≤ 50 | ppm | ICP-MS / ICP-OES |
| Sulphate (SO₄) | ≤ 0.005 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Free chlorine (Cl₂) | ≤ 0.001 | % | Iodometric / colorimetric limit test |
Grade 25300·01
Laboratory Reagent
Hydrochloric acid 35–37 %
- Typical applications
- General laboratory work, teaching laboratories, sample preparation
- Standard / basis
- Meets ISO 6353-2 requirements for laboratory reagents
- Density
- 1.18 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 500 mL | Amber glass bottle | 253000123 | |
| 2.5 L | Amber glass bottle | 253000142 | |
| 5 L | HDPE container | 253000144 | |
| 25 L | HDPE container | 253000162 | |
| 200 L | HDPE container | 253000164 | |
| 1000 L | HDPE container | 253000181 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 35.0 – 37.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 20 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after ignition | ≤ 0.002 | % | Gravimetric, ACS Reagent Chemicals |
| Free chlorine (Cl₂) | ≤ 0.0005 | % | Iodometric / colorimetric limit test |
| Sulphate (SO₄) | ≤ 0.001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Sulphite (SO₃) | ≤ 0.001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Ammonium (NH₄) | ≤ 0.001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Iron (Fe) | ≤ 0.0005 | % | ICP-MS / ICP-OES |
| Heavy metals (as Pb) | ≤ 0.0005 | % | Sulfide colorimetric limit test (as Pb), ACS |
Grade 25300·02
Analytical Reagent
Hydrochloric acid 36.5–38 %
- Typical applications
- Quantitative analysis, titrimetry, AAS digestion, pharmacopoeial testing
- Standard / basis
- Complies with ACS Reagent Chemicals, ISO 6353-2 and Ph. Eur. requirements
- Density
- 1.19 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 500 mL | Amber glass bottle | 253000223 | |
| 2.5 L | Amber glass bottle | 253000242 | |
| 5 L | HDPE container | 253000244 | |
| 25 L | HDPE container | 253000262 | |
| 200 L | HDPE container | 253000264 | |
| 1000 L | HDPE container | 253000281 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 36.5 – 38.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 10 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after ignition | ≤ 0.0005 | % | Gravimetric, ACS Reagent Chemicals |
| Free chlorine (Cl₂) | ≤ 0.0001 | % | Iodometric / colorimetric limit test |
| Bromide (Br) | ≤ 0.005 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Sulphate (SO₄) | ≤ 0.0001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Sulphite (SO₃) | ≤ 0.0001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Ammonium (NH₄) | ≤ 0.0003 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Arsenic (As) | ≤ 0.01 | ppm | Hydride-generation AAS / ICP-MS |
| Iron (Fe) | ≤ 0.0001 | % | ICP-MS / ICP-OES |
| Heavy metals (as Pb) | ≤ 0.0001 | % | Sulfide colorimetric limit test (as Pb), ACS |
| Extractable organic substances | Passes test | Extraction and gravimetric limit test, ACS |
Grade 25300·03
PV Pure
Hydrochloric acid 30–32 %
- Typical applications
- Photovoltaic wafer texturing, etching and cleaning
- Standard / basis
- Manufactured to our PV Pure specification
- Density
- 1.15 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 25 L | HDPE container | 253000362 | |
| 200 L | HDPE container | 253000364 | |
| 1000 L | IBC tank | 253000381 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 30.0 – 32.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 10 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after ignition | ≤ 0.0005 | % | Gravimetric, ACS Reagent Chemicals |
| Free chlorine (Cl₂) | ≤ 0.0001 | % | Iodometric / colorimetric limit test |
| Sulphate (SO₄) | ≤ 0.0001 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Total metallic impurities | ≤1 | ppm | ICP-OES / ICP-MS, sum of listed elements |
Trace metals — limits in ppb (µg/l) · 10 elements
Trace metals are determined by ICP-MS in our Class 100 clean-room laboratory after high-purity dilution, and the limits apply to the product as packed. Once an ultrapure pack is opened, the trace-metal specification can no longer be guaranteed.
Grade 25300·04
Ultrapure PPB
Hydrochloric acid 34–37 %
- Typical applications
- Semiconductor wet processing, trace metal analysis, ICP and AAS work
- Standard / basis
- Trace metals to our ultrapure specification below
- Density
- 1.18 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 500 mL | Clear glass / PU-coated Safebreak / FEP | 253000423 | |
| 1 L | Clear glass / PU-coated Safebreak / FEP | 253000441 | |
| 2.5 L | Clear glass / PU-coated Safebreak / FEP | 253000442 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 34.0 – 37.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 10 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after evaporation | ≤ 0.0005 | % | Gravimetric, ACS Reagent Chemicals |
| Free chlorine (Cl₂) | ≤ 0.00005 | % | Iodometric / colorimetric limit test |
| Sulphate (SO₄) | ≤ 0.00005 | % | Turbidimetric / colorimetric limit test (ACS) or ion chromatography |
| Particles > 0.5 µm | ≤ 100 | per ml | Liquid-borne particle counter (light scattering) |
Trace metals — limits in ppb (µg/l) · 65 elements
Trace metals are determined by ICP-MS in our Class 100 clean-room laboratory after high-purity dilution, and the limits apply to the product as packed. Once an ultrapure pack is opened, the trace-metal specification can no longer be guaranteed.
Grade 25300·14
Ultrapure PPB (30 %)
Hydrochloric acid 30 %
- Typical applications
- Semiconductor cleaning baths specified at lower concentration
- Standard / basis
- Trace metals to our ultrapure specification below
- Density
- 1.15 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 1 L | Clear glass / PU-coated Safebreak / FEP | 253001441 | |
| 2.5 L | Clear glass / PU-coated Safebreak / FEP | 253001442 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 29.5 – 30.5 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 10 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after evaporation | ≤ 0.0005 | % | Gravimetric, ACS Reagent Chemicals |
| Free chlorine (Cl₂) | ≤ 0.00005 | % | Iodometric / colorimetric limit test |
| Particles > 0.5 µm | ≤ 100 | per ml | Liquid-borne particle counter (light scattering) |
Trace metals — limits in ppb (µg/l) · 65 elements
Trace metals are determined by ICP-MS in our Class 100 clean-room laboratory after high-purity dilution, and the limits apply to the product as packed. Once an ultrapure pack is opened, the trace-metal specification can no longer be guaranteed.
Grade 25300·05
Ultrapure PPT
Hydrochloric acid 34–37 %
- Typical applications
- ICP-MS trace analysis, advanced wafer fabrication, ultratrace digestion
- Standard / basis
- Trace metals at parts-per-trillion level — limits set from batch validation
- Density
- 1.18 g/ml (20 °C)
Pack sizes and SKUs
| Pack | Container | SKU | Add |
|---|---|---|---|
| 250 mL | FEP bottle, clean-room packed | 253000522 | |
| 500 mL | FEP bottle, clean-room packed | 253000523 | |
| 1 L | FEP bottle, clean-room packed | 253000541 |
Release specification
| Parameter | Limit | Unit | Method (typical) |
|---|---|---|---|
| Assay (HCl) | 34.0 – 37.0 | % | Titrimetry (acid–base / redox), ACS / Ph. Eur. method |
| Appearance | Clear, colourless liquid | Visual, against water in matched tubes | |
| Colour | ≤ 10 | APHA | APHA / Hazen, ASTM D1209 |
| Residue after evaporation | ≤ 0.0001 | % | Gravimetric, ACS Reagent Chemicals |
| Particles > 0.5 µm | ≤ 25 | per ml | Liquid-borne particle counter (light scattering) |
Trace metals at parts-per-trillion level · 65 elements monitored
Limits for this grade come from batch validation. Each certificate of analysis reports them at ppt level.
Al Sb As Ba Be Bi B Cd Cs Ca Ce Cr Co Cu Dy Er Eu Gd Ga Ge Au Hf Ho In Ir Fe La Pb Li Lu Mg Mn Hg Mo Nd Ni Nb Os Pd Pt K Pr Re Rh Rb Ru Sm Sc Se Ag Na Sr Ta Te Tb Tl Tm Sn Ti W V Yb Y Zn Zr
Reference standards
- Laboratory Reagent (LR): meets ISO 6353-2 requirements for laboratory reagents.
- Analytical Reagent (AR): complies with ACS Reagent Chemicals (current edition), ISO 6353-2 and Ph. Eur. monograph requirements where a monograph exists.
- PV Pure: our photovoltaic specification — ten named metallic elements limited per the table for the grade.
- Ultrapure / Electronic grades: trace metals controlled to our ultrapure specification (ICP-MS, 65 elements). The parameter set follows SEMI C27 — Specification and Guide for Hydrochloric Acid; conformance to a specific SEMI grade or tier is confirmed per lot on the certificate of analysis and can be contracted on request.
- Test methods listed as "typical" are our release methods; equivalent ACS, Ph. Eur. or SEMI C1 methods may be substituted by agreement.
Limits shown as "≤" are the maximum values a lot is released against, and an assay range is the guaranteed window. We manufacture tightened limits, bespoke concentrations and non-standard packs to order.