ISO 9001 · ISO 14001 · ISO 45001 certified manufacturer+91 82002 09166office@satyendrafinechem.com
Satyendra Fine Chem

Products · Water · product 30100

High-purity water

Thirteen water grades, covering demineralised water through 18.2 MΩ·cm ultrapure, ICP-MS grade and LC-MS grade.

Grades

Grade 30100·04

Ultrapure PPB

Water, ultrapure

Typical applications
Ultratrace analysis, semiconductor rinse, standard preparation
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301000423
1 LHDPE bottle301000441
2.5 LHDPE bottle301000442
5 LHDPE container301000444
25 LHDPE container301000462

Release specification

ParameterLimitUnitMethod (typical)
Resistivity at 25 °C18.2MΩ·cmConductivity / resistivity meter, temperature-compensated
TOC≤5ppbTOC analyser (UV-persulfate / NDIR)
Trace metals, each element≤ 0.1ppbACS / ISO 6353-2 limit test
Particles > 0.2 µm≤1per mlLiquid-borne particle counter (light scattering)
Bacteria≤1CFU/mlMembrane filtration plate count / LAL

Grade 30100·14

ICP-MS Grade

Water, ICP-MS grade

Typical applications
ICP-MS and ICP-OES blank and standard preparation
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301001423
1 LHDPE bottle301001441
2.5 LHDPE bottle301001442
5 LHDPE container301001444
25 LHDPE container301001462

Release specification

ParameterLimitUnitMethod (typical)
Resistivity at 25 °C≥ 18.0MΩ·cmConductivity / resistivity meter, temperature-compensated
TOC≤ 10ppbTOC analyser (UV-persulfate / NDIR)
Trace metals, each element≤ 0.1ppbACS / ISO 6353-2 limit test
Particles > 0.2 µm≤1per mlLiquid-borne particle counter (light scattering)

Grade 30100·02

IC Grade

Water, IC grade

Typical applications
Ion chromatography eluent and blank preparation
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301000223
1 LHDPE bottle301000241
2.5 LHDPE bottle301000242
5 LHDPE container301000244
25 LHDPE container301000262

Release specification

ParameterLimitUnitMethod (typical)
Resistivity at 25 °C≥ 18.0MΩ·cmConductivity / resistivity meter, temperature-compensated
TOC≤ 20ppbTOC analyser (UV-persulfate / NDIR)
Chloride (Cl)≤1ppbTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Sulphate (SO₄)≤1ppbTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Nitrate (NO₃)≤1ppbTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Sodium (Na)≤1ppbICP-MS / ICP-OES

Grade 30100·12

ULC-MS Grade

Water, ULC-MS grade

Typical applications
Ultra-low background LC-MS, proteomics and metabolomics
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301001223
1 LHDPE bottle301001241
2.5 LHDPE bottle301001242
5 LHDPE container301001244
25 LHDPE container301001262

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤ 0.1µS/cmConductivity / resistivity meter, temperature-compensated
TOC≤ 10ppbTOC analyser (UV-persulfate / NDIR)
Evaporation residue≤ 0.5ppmGravimetric, ACS Reagent Chemicals
Gradient at 254 nm≤1mAUHPLC gradient / fluorescence background test

Grade 30100·22

LC-MS Grade

Water, LC-MS grade

Typical applications
LC-MS mobile phase and sample dilution
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301002223
1 LHDPE bottle301002241
2.5 LHDPE bottle301002242
5 LHDPE container301002244
25 LHDPE container301002262

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤ 0.2µS/cmConductivity / resistivity meter, temperature-compensated
TOC≤ 30ppbTOC analyser (UV-persulfate / NDIR)
Evaporation residue≤1ppmGravimetric, ACS Reagent Chemicals
Gradient at 254 nm≤2mAUHPLC gradient / fluorescence background test

Grade 30100·32

HPLC Grade

Water, HPLC grade

Typical applications
HPLC mobile phase, gradient elution, sample dilution
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301003223
1 LHDPE bottle301003241
2.5 LHDPE bottle301003242
5 LHDPE container301003244
25 LHDPE container301003262

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤ 1.0µS/cmConductivity / resistivity meter, temperature-compensated
TOC≤ 50ppbTOC analyser (UV-persulfate / NDIR)
Evaporation residue≤1ppmGravimetric, ACS Reagent Chemicals
Absorbance at 254 nm≤ 0.01AUUV spectrophotometry, 1 cm cell vs water
Filtration0.2µmMembrane filtration at bottling

Grade 30100·42

TOC Analysis

Water, for TOC analysis

Typical applications
Blank and system suitability for TOC instrumentation
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301004223
1 LHDPE bottle301004241
2.5 LHDPE bottle301004242
5 LHDPE container301004244
25 LHDPE container301004262

Release specification

ParameterLimitUnitMethod (typical)
Resistivity at 25 °C≥ 18.0MΩ·cmConductivity / resistivity meter, temperature-compensated
TOC≤5ppbTOC analyser (UV-persulfate / NDIR)
Conductivity at 25 °C≤ 0.056µS/cmConductivity / resistivity meter, temperature-compensated

Grade 30100·01

Demineralised

Water, demineralised

Typical applications
General laboratory rinsing, reagent and buffer make-up
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301000123
1 LHDPE bottle301000141
2.5 LHDPE bottle301000142
5 LHDPE container301000144
25 LHDPE container301000162

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤5µS/cmConductivity / resistivity meter, temperature-compensated
Evaporation residue≤5ppmGravimetric, ACS Reagent Chemicals
Chloride (Cl)≤ 0.2ppmTurbidimetric / colorimetric limit test (ACS) or ion chromatography

Grade 30100·11

Double Distilled, Pyrogen Free

Water, double distilled, pyrogen free

Typical applications
Cell culture media, endotoxin-sensitive preparations
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301001123
1 LHDPE bottle301001141
2.5 LHDPE bottle301001142
5 LHDPE container301001144
25 LHDPE container301001162

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤2µS/cmConductivity / resistivity meter, temperature-compensated
Evaporation residue≤2ppmGravimetric, ACS Reagent Chemicals
Endotoxin≤ 0.25EU/mlMembrane filtration plate count / LAL
Nitrate (NO₃)≤ 0.2ppmTurbidimetric / colorimetric limit test (ACS) or ion chromatography

Grade 30100·21

Ammonium Free

Water, ammonium free

Typical applications
Nitrogen and ammonium determinations
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301002123
1 LHDPE bottle301002141
2.5 LHDPE bottle301002142
5 LHDPE container301002144
25 LHDPE container301002162

Release specification

ParameterLimitUnitMethod (typical)
Ammonium (NH₄)≤ 0.05ppmTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Conductivity at 25 °C≤2µS/cmConductivity / resistivity meter, temperature-compensated
Evaporation residue≤2ppmGravimetric, ACS Reagent Chemicals

Grade 30100·31

Distilled

Water, distilled

Typical applications
General laboratory use, glassware rinsing
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301003123
1 LHDPE bottle301003141
2.5 LHDPE bottle301003142
5 LHDPE container301003144
25 LHDPE container301003162

Release specification

ParameterLimitUnitMethod (typical)
Conductivity at 25 °C≤3µS/cmConductivity / resistivity meter, temperature-compensated
Evaporation residue≤3ppmGravimetric, ACS Reagent Chemicals
pH5.0 – 7.0pH electrode at 25 °C

Grade 30100·41

Nitrate Free

Water, nitrate free

Typical applications
Nitrate and nitrite determinations
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301004123
1 LHDPE bottle301004141
2.5 LHDPE bottle301004142
5 LHDPE container301004144
25 LHDPE container301004162

Release specification

ParameterLimitUnitMethod (typical)
Nitrate (NO₃)≤ 0.05ppmTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Nitrite (NO₂)≤ 0.02ppmTurbidimetric / colorimetric limit test (ACS) or ion chromatography
Conductivity at 25 °C≤2µS/cmConductivity / resistivity meter, temperature-compensated

Grade 30100·51

Particle Free

Water, particle free

Typical applications
Particle counting, optical and filtration work
Standard / basis
our internal specification

Pack sizes and SKUs

PackContainerSKUAdd
500 mLHDPE bottle301005123
1 LHDPE bottle301005141
2.5 LHDPE bottle301005142
5 LHDPE container301005144
25 LHDPE container301005162

Release specification

ParameterLimitUnitMethod (typical)
Particles > 0.2 µm≤1per mlLiquid-borne particle counter (light scattering)
Conductivity at 25 °C≤1µS/cmConductivity / resistivity meter, temperature-compensated
Filtration0.2µmMembrane filtration at bottling

Reference standards

  • Water grades: ASTM D1193 (Types I–IV) and ISO 3696 (Grades 1–3) define the resistivity, TOC and particle classes; the Satyendra grade names map to the application rather than to a single ASTM type.
  • Ultrapure / Electronic grades: trace metals controlled to our ultrapure specification (ICP-MS, 65 elements). The parameter set follows SEMI F63 — Guide for Ultrapure Water Used in Semiconductor Processing; ASTM D1193 Type I; ISO 3696 Grade 1; conformance to a specific SEMI grade or tier is confirmed per lot on the certificate of analysis and can be contracted on request.
  • Test methods listed as "typical" are our release methods; equivalent ACS, Ph. Eur. or SEMI C1 methods may be substituted by agreement.

Limits shown as "≤" are the maximum values a lot is released against, and an assay range is the guaranteed window. We manufacture tightened limits, bespoke concentrations and non-standard packs to order.